Interface guide · drawing coordination

Welded Mesh Fence Gates, Corners & Slopes

Identify every interface before quotation and drawing approval without copying generic post, foundation or installation values into the project.

Installation reference · external video

See how one panel system handles straight runs, angles and slopes.

This short demonstration helps a buyer visualize why corners, gradients and trimmed panels must be identified before the supplier releases a coordinated drawing.

Transferable lesson: interface geometry changes the hardware and panel treatment. Put each gate, corner, slope, end and cut panel on the drawing instead of assuming one straight-run detail covers it.

Source boundary: the video is published by Betafence and demonstrates its UpGrade system. It is not an XIEHENG installation instruction and does not confirm our components, post spacing, foundations, capacity or project compliance.

Page responsibility

One page, one decision.

Use this guide for the stated decision, then move the result into the next project step.

This page decides

Which gate, corner, slope, end and transition interfaces must appear in quotation and drawing review.

This page does not decide

Universal post spacing, foundations, anchors, loads or installation-release values.

Carry forward

Give each interface an ID and close assumptions, component scope and responsibility before approval.

Direct answer

Gates, corners and slopes are system interfaces, not minor accessories.

They change geometry, terminal conditions, post and connection requirements, bottom gaps, drawings, quantities and responsibility. Identify them before the supplier fixes the quotation basis.

Mark every gate, corner, end, return, change in level and transition on the fence-line plan. Provide the required opening or boundary condition and ask the supplier to show the proposed interface in the quotation or drawing. This page collects inputs; it does not publish universal post spacing, foundation size, load capacity or installation-release values.

Read the line as a sequence of interfaces.

Numbering each location gives drawings, bills of material and review comments a shared reference.

G01 · GateLocation, clear opening, leaf arrangement, opening direction, duty cycle, latch/lock, controls, threshold and adjacent fence transition.
C01 · CornerDirection change, internal/external condition, level, terminal or continuous arrangement, finish continuity and nearby gate.
S01 · SlopeStart/end level, gradient or surveyed points, step/rake preference, bottom-gap limit, erosion or drainage feature.
E01 · EndFree end, return, wall, column, existing fence or another system; show access and fixing constraints.
T01 · TransitionChange of height, mesh, topping, finish, panel/roll form, foundation or responsibility boundary.

Coordinate each interface before approval.

The values below are information requests, not generic design instructions.

Interface Buyer or designer provides Supplier confirms
Gate Location, clear width/height, movement, usage, lock/control concept, access and local constraints. Gate configuration, frame/infill, posts, hinges, latch/lock scope, adjacent connection, finish and exclusions.
Corner or end Alignment, angle, levels, available base, obstruction and required boundary continuity. Terminal/corner arrangement, post and fixing concept, panel or roll termination, quantity and drawing reference.
Slope or step Surveyed geometry, acceptable bottom gap, appearance requirement, drainage and maintenance route. Whether the offered system steps, rakes or needs special modules; resulting gaps, transitions and non-standard items.
Wall or structure Substrate information, ownership, allowable fixing zone, services and waterproofing constraints. Proposed interface, loads or inputs required, supplied brackets/anchors and explicit design or installation boundary.
Change of system Required performance and exact change location. Overlap or termination detail, compatible components, finish continuity and responsibility at the joint.

Use the drawing review as a release gate.

A quotation can carry allowances, but manufacture should follow an approved, revision-controlled interface basis.

01 · Annotate

Issue the plan and elevations with unique gate, corner, slope, end and transition references.

02 · Propose

Supplier returns the offered configuration, special components, assumptions, exclusions and required inputs.

03 · Coordinate

Project team resolves bases, services, drainage, controls, access, local requirements and design ownership.

04 · Approve

Release supply only after drawing revision, quantities, finish, scope, packing and responsibilities are accepted.

Keep engineering values project-specific.

No drawing should inherit a foundation, anchor, post spacing, wind, impact or gate value from a generic webpage.

Technical confirmation boundary